Model Number: DT-REF
Conductor Material: Tin-round copper
Insulation Material: ultra-thin elastomer
Jacket: TPU polymer sheath
Number of Conductors: single-core
Application: railway passenger trains or the same vehicles
colou: black
Packaging & Delivery
Packaging Details:Depending on customers' requirements
Delivery Detail:10/15 days after full payments
1.Implemented standard:
TB/T1484-2001
2.Flame-retardant:
Conductors can be subjected successfully to tests specified by 5.3.4.4 of UIC895.
with good property of flame-retardant,
3.Safety performance:
Fire resistance class of finished cables complies with Class B of Appendix 9 of UIC564-2.
4.Heat resistance:
Be able to bear high heat 100-125°C,low heat -40°C
5.Ozone resistance:
Under the test conditions specified by Rule 5.2.4 of UIC895, ozone concentration is in air between 0.025% and 0.030% of volume, insulation layers, jackets or single-layer insulation shall be no cracks and fissures after put for 3h.
6.Moisture resistance of insulation:
The cable insulation be quite stable even in humid conditions. In the specified test condition, the cables can endure DC test voltage of 1 kV without breakdown.