Model Number: DECH
Conductor Material: Tinned copper conductor
Insulation Material: EPR(ethylene propylene rubber)
Jacket: CSM(chlorosulfonated polyethylene)
Number of Conductors: single core
Application: suitable for railway locomotive&car with rated voltage<=3kv
Packaging & Delivery
Packaging Details:Depending on customers' requirements
Delivery Detail:According to customer's requirements,usually 10~15 days
Description
Resistant to mineral oil and fuel oil ,heat-resistant 100°C
Construction
1.copper core 2.ethylene propylene rubber insulation 3.chorosulfonated polyethylene rubber compound or synthetic elastomer sheath
Application
This product implements GB/T12528-2008, applied AC rated voltage of 3kV and below the railway locomotive power transmission.
Electrical & Mechanical Properties
1.Cable AC rated voltage U0 is 750V,1.5kV and 3kV, DC rated voltage is 1.5 times of the AC rated voltage.
2.Cable’s long-term allowable working temperature is 100 °C.
3.The lowest temperature environment is -25°C of cable working.
4.Bending radius of cable installation: cable diameter (D) is 20mm and the following shall be not less than 6D, cable diameter (D) is 20mm or more shall be not less than 8D.
Chemical & Environmental Properties
EN 60684-2 | No fluorine |
EN 50305; EN 60811-2-1 | Resistance to oil & fuel |
EN 50305 | Resistance to ozone |
Fire Performance for rolling stock application
EN 50306-2 | Hazard levels HL1, HL2/HL3, HL4 |
DIN 5510-2 | Protection level 1/2/3/4 |
BS 6853 | Interior use 1a, 1b, II; Exterior use 1a, 1b, II |
NF F 16-101 | FO |
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3C; | Fire propagation of bunched wires and cables; |
VDE 0472 Teil 804; BS 4066-3; NFC 32070 | |
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 | Smoke density |
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 | Corrosivity of gases (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Toxicity index |
NFF 16101; NFF 63808; BS6853 | Smoke index |