8.7/15KV XLPE Insulation STA armoured Power Cable


Model Number: YJ(L)V22 V(L)V22
Type: Insulated, High voltage
Application: Power Station
Conductor Material: Copper or Aluminum
Conductor Type: Stranded
Insulation Material: XLPE

Packaging & Delivery
Packaging Details:Packed in drums,cases or according to your requirement
Delivery Detail:Within 5-15 working days or according to your requirement

Application
It is used in power plant or power station ,it can be direct buried or in ground, it can bear external mechanical forces.

Construction
1.jpg
1.Conductor     2.Insulation     3.Inner sheath     4.Steel tape armoured     5.Steel wire armoured     6.Sheath

Technical  data
Rated voltage:8.7/15KV
Highest working temperatue of conductor: 90°C
Laying temperature:above 0°C
Minimum bending radius:12D

Product  description

TypeDescriptionApplication
CuAl
YJVYJLVCopper-core(aluminum core)XLPE insulation and PVC sheath power cableFor laying indoor,in tunnels and in ducts,unable to bear external mechanical forces
YJYYJLYCopper-core(aluminum core)XLPE insulation and PE sheath power cable
YJV22YJLV22Copper-core(aluminum core)XLPE insulation steel tape armoured PVC sheath power cableFor laying indoor,in tunnels and in ducts,can able to bear external mechanical forces
YJV23YJLV23Copper-core(aluminum core)XLPE insulation steel tape armoured PE sheath power cable
YJV32YJLV32Copper-core(aluminum core)XLPE insulation steel wire armoured PVC sheath power cableFor laying in water or ground along route with large difference of level,can able to bear external mechanical forces
YJV33YJLV33Copper-core(aluminum core)XLPE insulation steel wire armoured PE sheath power cable
YJV42YJLV42Copper-core(aluminum core)XLPE insulation thick wire armoured PVC sheath power cable
YJV43YJLV43Copper-core(aluminum core)XLPE insulation thick wire armoured PE sheath power cable
    
Notes:
1.Ratproof,termite-proof,moisture-proof and other special requiremments cables are available.           
2.The   single core armoured cable are used for DC system only.As for AC   system,non-megnetical materials shoule be used,its corresponding code is   62,63,72,73;           
3.It   is not recommended AL-core fire retardent cable.When there is a   fire,flame temperatures may reach 700°C above due to the meilting point   of aluminium is only 660°C,the conductor may be fused;          
4.Flame   retaradant/fire resistant power cable are available:Representation   method of flame retardant grade is the "Z" followed by"A","B","C",such   as the "ZA","ZB","ZC".When "ZR" expressed,generally considered to be "C"   class of flame retardant.Flame retardant level representation is "ZN"   middle "A","B","C",such as the "ZA","ZB","ZC".While using "NH"   expressed,it generally considered to be "ZCN".For example;